BRAD Breathing Air Systems

Available system packages:
  • BRAD-01B-One Man Setup
  • BRAD-02B
  • BRAD-4000B
  • BRAD-PERF-25B
  • BRAD-PERF-50B

PDF Link View PDF

BRAD-01B-One Man Setup BRAD-01B-One Man Setup BRAD-01B-One Man Setup

BRAD-01B-One Man Setup
Complete System Package

Prefilter Combo, CO Monitor, Belt Regulator, Full Face Mask, 35′ Hose Assembly, 4′ Whip Hose, 1/2″ Regulator w/ Gauge

Features
  • Ultra Lightweight Design
  • 35 Feet of Low Odor Non “Out-Gassing” Breathing Air Hose
  • Belt Mounted Full Diaphragm Regulator
  • Safest AFF-50 Rated Mask Ensures Safety of the User
  • Full Face NIOSH Approved Breathing Mask (TC#19C-353)
  • Double the Assigned Protection Factor (APF) of Competitor Supplied Air Hoods
  • Over-the-Shoulder Design Air Breathing Hose
  • High Flow Push-to-Make Connectors
  • Self Calibrating Monitor w/Audible Alarm; Displays Actual CO Levels & Alarms at 10ppm of CO
  • Monitor comes with 12 Volt Battery Back-up
  • Less Air Needed (3-4 scfm) to Feed Gun & Breathing System Unlike Competitors (15-17 scfm)

Operating kit provides the safest NIOSH approved mask design with 35′ air supply hose. Unit is light weight and mask provided has a wide field of vision. It’s the safest supplied air respirator offered. Meets OSHA standards [29CFR 1910.134(d)(1)].

BRAD-PC1BBRAD-PC1B
Prefilter / CO Monitor (for use with customer supplied mask)

This breathing air filter system provides the safest breathing air to your application available. The unit is to be serviced every 3 months and can be serviced in less than 5 minutes. The monitor design is directly inline with the air flow ensuring consistent, safe monitoring.

Features
  • Inlet Shutoff Valve
  • Patented “Inverse Flow™” 1st Stage
  • Deep Activated Carbon Bed
  • 0.01 micron Coalescing Final Filter
  • Rapid Service Bowl Assembly
  • Easy Filter Element Replacement
  • Non Leaking Auto Drain
  • Self Calibrating Monitor with Audible Alarm and Display
  • High Flow Diaphragm Regulator
BRAD-4000B

Complete System Package with Desiccant

Prefilter Combo, Desiccant Tower, CO Monitor, Operators Kit

BRAD-02B
Complete 2 Man System Package

Includes 2 Man Prefilter Combo Unit, CO Monitor, 1/2″ Regulator w/Gauge, 2 Operators Kits

Accessories
BRAD-OK BRAD-CM2 BRAD-M1
BRAD-OK
Operators Kit
Includes Belt Regulator, Full Face Mask, and 35′ Hose Assembly
BRAD-CM2
CO Monitor
110VAC w/12Volt Battery Back-up
BRAD-M1
Full Face Mask Supplied Air Respirator-NIOSH Approved
HVHA-B35 BRAD-M1-LC BRAD-060-M04
HVHA-B35
35′ Operator Hose, 3/8″ w/ Quick Disconnect
BRAD-M1-LC
Replacement Lens Cover for Mask
BRAD-060-M04
Prefilter used in BRAD-01B System
MR-1 HVHA-B04  
MR-1
Mini Paint Regulator
HVHA-B04
4′ Whip Hose Assembly
 
BRAD-PERF 25-50BRAD-PERF 25-50
Combination Breathing Air and Paint Gun System

CLEAN, DRY SPRAY & BREATHING AIR SUPPLY

Features & Benefits
  • Consistent less then -40°F Dew Point to the Gun Preferred by Paint MFR’s
  • Delivers Perfectly Clean, Dry Air for “Flawless Finishes Every Time”
  • Has the Most Activated Carbon of Any Competitive Breathing/Paint Air System on the Market
  • Engineered for Use with All Paint Spray Guns (not included) Especially HVLP Guns
  • Supplies Grade D Breathing Air
  • PERF-BRAD-25B Model for Single Gun Spraying; BRAD-PERF-50B for Two Gun Spraying Booths
  • Regenerative Desiccant Beds Require Little Maintenance
  • Monitor Design is Directly Inline with the Air Flow Ensuring Consistent, Safe Monitoring.
  • Self Calibrating Monitor w/Audible Alarm
  • Monitor Displays Actual CO Levels & Alarms at 10ppm of CO
Technical Specifications
  • Full Face Mask Respirator, which is NIOSH approved Supplied Air Respirator: TC#19C-353
  • BRAD-PERF-25, 150 scfm pre-filter system, with auto drain 1st stage, 1/2″NPT Inlet, 3/8″ FPT outlet to gun.
  • BRAD-PERF-50, 150 scfm pre-filter system, with auto drain 1st stage, 1/2″NPT Inlet, 1/2″ FPT outlet to gun.
Model
Description
 
Systems
BRAD-01B Delta Force System Package which includes:
BRAD-PC1 and BRAD-OK
BRAD-02B 2 Person Ultra Force System Package which includes:
BRAD-PC2B and (2) BRAD-OK
BRAD-4000B Desiccant Dryer System Package which includes:
BRAD-PC3B and BRAD-OK
BRAD-PERF-25B Perfect Air System which includes:
BRAD-PC2B, ARAD-25, (2) 1/2 Reg. w/Gauge & 3/8″ Reg. w/Gauge
BRAD-PERF-50B PerfectAir System which includes:
BRAD-PC2B, ARAD-50, (2) 1/2 Reg. w/Gauge & 3/4″ Reg. w/Gauge
 
Subassemblies/Accessories
BRAD-PC1B 1 Person, 2-Stage Prefilter Assembly with BRAD-CM2 CO Monitor
BRAD-PC2B 2 Person, 2-Stage Prefitler Assembly with BRAD-CM2 CO Monitor
BRAD-PC3B 1 Person PreFilter System with Desiccant Dryer & BRAD-CM2 CO Monitor
BRAD-OK Operators Kit which includes:
BRAD-F5 Belt-Mounted Regulator Assembly,
BRAD-M1 Full Face Mask & HVHA-B35 35′ Breathing Air Hose
BRAD-060-M04 Filter combo used in BRAD-PC1B
BRAD-150-M04 Filter combo used in BRAD-PC2B
BRAD-CM2 CO Monitor Assembly
BRAD-DE-M04 Filter system used in BRAD-PC3B
BRAD-F1 Belt Mounted Filter Assembly w/Activated Carbon Filter
BRAD-F2 Belt Mounted Filter Assembly w/CO Scrubbing Catalyst Filter
BRAD-F3 Belt Mounted Filter Assembly w/Activated Carbon Filter
BRAD-F4 Belt Mounted Filter Assembly w/CO Scrubbing Catalyst Filter
BRAD-F5 Belt Mounted Regulator Assembly
BRAD-G1 Calibration Kit for BRAD-CM
BRAD-G2 Calibration Kit for BRAD-CM2
BRAD-M1 Full Face Mask Supplied Air Respirator
BRAD-Z2-1 Manifold, Outlet . 2 Ports with On/Off Valves
BRAD-Z4-1 Manifold, Outlet . 4 Ports with On/Off Valves
HVHA-B04 4′ Whip Hose, . with Quick Disconnects
HVHA-B35 35′ Operator Hose, 3/8″ with Quick Disconnects
HVHA-B50 50′ Operator Hose 3/8″ with Quick Disconnects
MR-1 Mini Regulator with 0-60 Gauge
 
Replacement Parts/Kits
3C-060 Element, 2nd Stage . 0.01 Micron, Grade 2
3C-061 Element, 2nd Stage . 0.01 Micron, Grade 1
3C-151 Element, 2nd Stage . 0.01 Micron, Grade 1
4P-060 Element, 1st Stage . 1 Micron
BRAD-01B-MK 1 Year Element Maintenance Kit for BRAD-01B
BRAD-02B-MK 1 Year Element Maintenance Kit for BRAD-02B
BRAD-4000B-MK 1 Year Element Maintenance Kit for BRAD-4000B
BRAD-B1 Belt for BRAD-F1 through BRAD-F4
BRAD-E1 Replacement Element for BRAD-F1 and BRAD-F3
BRAD-E2 Replacement Element for BRAD-F2 and BRAD-F4
BRAD-M1-LC Lens Covers, Peel Off . package of 25
BRAD-M1-BT Breathing Tube Assembly, Mask
BRAD-M1-RL Replacement Lens, Mask
BRAD-M1-SK Spectacle Kit, Mask
BRAD-PERF-MK 1 Year Element Maintenance Kit for BRAD-PERF-25B & 50B Systems
DE362C Element, 1st Stage
DE401 Desiccant Element
N32-95-979 Drain, Automatic-1/4″ NPT Black
PC-03 Drain, Manual Petcock – 3/8″
PG-160 Pressure Gauge . 0-160 psig
PG-015 Pressure Gauge . 0-15 psig
PG-060-15C Pressure Gauge . 0-60 psig 1/4″ (for MR-1)